UL  135416911792 ( PECPE ) Shield  cable

   Figure
                 

1.ConductorAnnealed Copper Wire (Tinned Strand)
2.InsulationPE (Polyethylene) CPE ( Cellular Polyethylene)  
3.Wrapping ShieldAnnealed Copper Wire (Tinned Copper )
4.SheathPVC  ( Polyvinyl  Chloride)  
5.Structure

Conductor

CPE Insulation

Wrapping Shield

Sheath

AWG

Construction

Diameter

Min. Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

30

7 / 0.10TA

approx.
0.30 mm

0.40 mm

0.525 mm

1.40 ± 0.10 mm

44 / 0.10

approx.
1.60 mm

0.26mm

0.325mm

2.20 ± 0.10 mm

Conductor

PE  Insulation  (General)

Wrapping Shield

Sheath

30

7 / 0.10TA

approx.
0.30 mm

0.16 mm

0.25 mm

0.80 ± 0.10 mm

25 / 0.10

approx.
1.00 mm

0.175mm

0.275mm

1.55 ± 0.10 mm

Conductor

CPE  Insulation (General)

Wrapping Shield

Sheath

28

7 / 0.13TA

approx.
0.39 mm

0.38 mm

0.53 mm

1.45 ± 0.10 mm

37 / 0.12

approx.
1.69 mm

0.26mm

0.33mm

2.35 ± 0.10 mm

Conductor

CPE Insulation 
(for Apple)

Wrapping Shield

Sheath

28

7 / 0.13TA

approx.
0.39 mm

0.38 mm

0.605 mm

1.60 ± 0.10 mm

42 / 0.12

approx.
1.84 mm

0.224mm

0.305mm

2.45 ± 0.10 mm

                     

6.Characteristics  

Items

Specification

Rating

UL80℃ 30V

Dielectric Strength

AC 500V / min.

Spark Test AC 2000V / 0.15sec.

Insulation Resistance

Min.1000MW - Km (20) at DC 500V

Mutual  Capacitance

Depends on Different Specifications (1KHz)

7.MarkingTATUNG  E54979 AWM  1354  80  AWG    
              TATUNG  E54979 AWM  1691  80  AWG
              TATUNG  E54979 AWM  1792  80  AWG