PE – PVC  PCM ( T1 ) Switch board Cable

Figure
                 
1.ApplicationThis cable is used. for interconnecting between frames of PCM equipments
                          with 100
W characteristic impedance.
2.ConductorAnnealed bare copper wire.
3.InsulationPE (Polyethylene)
4.TwistTwo wires twisted to form a pair.
5.AssemblySuitable number of pairs assembled to form a cable core.
6.a.Mylar-aluminum tape for 1 pair.    b.Soft copper tape for 5 pairs and above.
7.SheathPVC (polyvinyl Chloride)       
8.Structure

Conductor

Pair (P)

Insulation

Cable core diameter

Sheath

Diameter overall

Standard

Diameter(mm)

 

Thickness(mm)

approx. (mm)

Thickness(mm)

(mm)

Length(M)

0.5

1

0.28

2.5

0.5

Max.3.6

200

0.5

8

0.26

6

1.0

approx.9

500

0.5

12

0.26

7

1.0

approx.10

500

0.5

30

0.26

11

1.0

approx.14

500

9.Characteristics

Items

Specification

Conductor Resistance

Max.93.5W / Km (20)

Insulation Resistance

Min.10000MW - Km(20,DC 500V / 1 min.)

Dielectric Strength

DC 300V / 3sec.(60Hz)between conductors

Static Capacitance

Avg.

51.6± 2.5nF / Km (1KHz)

Indivual

51.6± 3.7nF / Km (1KHz)

Attenuation.(772 KHz)

Max. Avg.19.5 dB / Km for 1 pair

Max.35 dB / Km for  8P, 12P , 30P

Characteristic Impedance

100 ± 10W (772 KHz)

NEXT (772 KHz)

m ¾ ³ 56 dB / 500M (less than 12paire)

m ¾ ³ 60 dB / 500M (30paire)

mavg.value

△:Standard difference

10.MarkingTATUNG CO. PCM-E1 0.5 ´ P Year  M