PE – PVC  PCM (E1) Switch board Cable

   Figure
                 
1. ApplicationThis cable is used. for interconnecting between frames of PCM equipments
                  with 120
W characteristic impedance.
2. ConductorAnnealed bare copper wire.
3. InsulationPE (Polyethylene)
4. TwistTwo wires twisted to form a pair.
5. AssemblySuitable number of pairs assembled to form a cable core.
6. a.Mylar-aluminum tape for 1 pair.    b.Soft copper tape for 5 pairs and above.
7. SheathPVC (polyvinyl Chloride) 
8. Structure
 

Conductor

Pair (P)

Insulation

Cable core diameter

Sheath

Diameter overall

Standard

Diameter(mm)

 

Thickness(mm)

approx. (mm)

Thickness(mm)

(approx.)

Length(M)

0.5

1

0.38

2.5

0.5

3.6

200

0.5

5

0.40

6.2

1.0

8.3

500

0.5

10

0.40

8.5

1.0

11.2

500

0.5

25

0.40

12.6

1.0

15.3

500

9. Characteristics

Items

Specification

Conductor Resistance

Max.93.5MΩ / Km (20℃)

Insulation Resistance

Min.10000MΩ - Km(20℃,DC 500V / 1 min.)

Dielectric Strength

DC 300V / 3sec.(60Hz)between conductors

Static Capacitance

Avg.

Max. 50nF / Km (1KHz)

Attenuation.(1024KHz)

Max.22 dB / Km

Characteristic Impedance

120 ± 10Ω(1024KHz)

NEXT (1024KHz)

m - 56 dB / 500M (less than 15paire)

m - △≧ 60 dB / 500M (25paire)

mavg.value

△:Standard difference

10. MarkingTATUNG CO. PCM-E1 0.5 ´ P Year  M