UL  2562  Parallel Shield Wise

   Figure
                 
1.ConductorTinned Copper Strand.                    
2.InsulationPVC (Polyvinyl Chloride )  
3.Wrapping ShieldBare or Tinned Copper Wires Wrapping on Insulation  
4.SheathPVC( Polyvinyl  Chloride)    
5.Structure
 

Conductor

Insulation

Wrapping Shield

Sheath

AWG

Construction

Diameter

Min.  
Thickness

Nominal  
Thickness

Diameter

Construction

Diameter

Min.  
Thickness

Nominal  
Thickness

Diameter

26

7 / 0.16TA×2C

approx.
0.48 mm

0.331 mm

0.41mm

1.30 ± 0.10 mm

33 / 0.12 mm

1.54 mm

0.331mm

0.53mm

2.60 ± 0.10 mm
X5.20 ± 0.20 mm

26

7 / 0.16A×2C

approx.
0.48mm

0.331 mm

0.41 mm

1.30 ± 0.10 mm

33 / 0.12 mm

1.54 mm

0.331mm

0.53mm

2.60 ± 0.10 mm  
X5.20 ± 0.20 mm

24

11/ 0.16A×2C

approx.
0.61 mm

0.331 mm

0.445 mm

1.50± 0.10 mm

37 / 0.12 mm

1.74 mm

0.331mm

0.48mm

2.70 ± 0.10 mm
X5.40 ± 0.20 mm

22

7 / 0.26A×2C

approx.
0.78mm

0.331 mm

0.46 mm

1.70 ± 0.10 mm

42 / 0.12 mm

1.74 mm

0.331mm

0.53mm

3.00 ± 0.10 mm
X6.00
± 0.20 mm

26

7 / 0.16TA×3C

approx.
0.48 mm

0.331 mm

0.41 mm

1.30 ± 0.10 mm

33 / 0.12 mm

1.54 m

0.331mm

0.53mm

2.60 ± 0.10 mm
X7.80
± 0.20 mm

                       

6.Characteristics

Items

Specification

Rating

UL80   30V

Dielectric Strength

Spark Test AC2000V / 0.15sec.

Insulation Resistance

Min.5MW - Km (20) at DC 500V

Flame Test

ULVW – 1 

7.MarkingE54979 AWM  2562   80 300V   VW – 1SC  AWG   TATUNG 
                        LL58500  CSA  TR – 64  90  FT1