UL  1792  (CPE) Shield  Wire

   Figure
                 
1.ConductorStrand Tinned Copper Wire
2.InsulationCPE (Cellular Polyethylene)  
3.Wrapping ShieldTinned Copper Wires Wrapped on Insulation.
4.SheathPVC( Polyvinyl  Chloride)  
5.Structure

Conductor

Insulation

Shield

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Construction

Al-Mylar
Tape

Min.
Thickness

Nominal
Thickness

Diameter

28

7 / 0.13TA

approx.
0.39mm

0.38 mm

0.48 mm

1.35±0.10
mm

36 / 0.12

0.025 × 6mm
longitudinal

0.47mm

0.60mm

2.80±0.10
mm

6.Characteristics

Items

Specification

Rating

UL80  30V

Dielectric Strength

Spark Test AC 2000V / 0.15sec.

Insulation Resistance

Min.5MW - Km (20) at DC 500V

Mutual  Capacitance

63 ± 5pf / m at 1KHz

Flame Test

ULVW - 1

7.MarkingTATUNG  E54979 AWM  1792   80  VW – 1SC  AWG