UL  1691 (FRPE) Insulation Aluminum Shield Wire

   Figure
                 
1.ConductorTop-Tinned Copper Strand or Tinned Single. 
2.InsulationFRPE (Flame Retardant Polyethylene)   
3.Drain WireTop-Tinned Copper Strand or Tinned Single.
4.ShieldAl-Mylar Tape Longitudinally Folded Around Insulation and Drain Wire.
5.SheathPVC (Polyvinyl  Chloride)
6.Structure

Conductor

Insulation

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Al-mylar
Tape

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

30

7 / 0.102ATC

approx.0.306 mm

0.102 mm

0.27 mm

0.85 ± 0.10 mm

0.025 × 6 mm

7 / 0.102

0.127mm

0.40mm

1.70 ± 0.10 mm
X1.90
± 0.10mm

28

7 / 0.13ATC

approx.0.39 mm

0.102 mm

0.25 mm

0.92 ± 0.10 mm

0.025 × 6 mm

7 / 0.13

0.127mm

0.40mm

1.80 ± 0.10 mm
X2.10
± 0.10mm

26

7 / 0.16ATC

approx.0.48 mm

0.102 mm

0.26 mm

1.00± 0.10 mm

0.025 × 6 mm

7 / 0.16

0.127mm

0.40mm

1.90 ± 0.10 mm
X2.40
± 0.10mm

24

7 / 0.20ATC

approx.0.60 mm

0.102 mm

0.25 mm

1.10 ± 0.10 mm

0.025 × 6 mm

7 / 0.20

0.127mm

0.40mm

2.00 ± 0.10 mm
X2.50
± 0.10mm

24

1 / 0.51TA

approx.0.51 mm

0.102 mm

0.29 mm

1.10 ± 0.10 mm

0.025 × 6 mm

7 / 0.51

0.127mm

0.40mm

2.00 ± 0.10 mm
X2.50 ± 0.10mm

   NoteTATinned Copper ,  ATCTop – Tinned  Strand  Copper Wire.

7.Characteristics

Items

Specification

Rating

UL80 30V

Dielectric Strength

Spark Test AC 2000V / 0.15sec.

Insulation Resistance

Min.5MW - Km (20) at DC 500V

Flame Test

ULVW – 1

8.MarkingE54979 AWM  1691  30V - 80  VW – 1SC  AWG   TATUNG