UL  1691 FRPE Insulation Shield Wire

   Figure
                 
1.ConductorBare or Tinned Copper Strand
2.InsulationFRPE (Flame Retardant Polyethylene) 
3.Wrapping ShieldBare or Tinned Copper Wires Wrapped on Insulation
4.SheathPVC ( Polyvinyl  Chloride)  
5.Structure

Conductor

Insulation

Wrapping Shield

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

28

7 / 0.13TA

approx.
0.39 mm

0.22 mm

0.265 mm

0.92 ± 0.10 mm

28 / 0.10

approx.1.12 mm

0.192mm

0.24mm

1.60 ± 0.10 mm

26

7 / 0.16TA

approx.
0.48 mm

0.208 mm

0.26 mm

1.00 ± 0.10 mm

31 / 0.10

approx.1.05 mm

0.20mm

0.25mm

1.70 ± 0.10 mm

24

7 / 0.20TA

approx.
0.60 mm

0.20 mm

0.25 mm

1.10 ± 0.10 mm

33 / 0.10

approx.1.30 mm

0.20mm

0.25mm

1.80 ± 0.10 mm

24

11 / 0.16TA

approx.
0.61 mm

0.196 mm

0.245 mm

1.10 ± 0.10 mm

33 / 0.10

approx.1.30 mm

0.20mm

0.25mm

1.80 ± 0.10 mm

    NoteTATinned Copper ,  ABare  Copper

6.Structure

Items

Specification

Rating

UL80 30V

Dielectric Strength

Spark Test AC 2000V / 0.15sec.

Insulation Resistance

Min.5MW - Km (20) at DC 500V

Flame Test

ULVW – 1

7.MarkingE54979 AWM  1691  30V - 80   VW – 1SC  AWG   TATUNG