UL 1571 PVC Insulation Wire

   Figure
                 
1.ConductorAnnealed Copper Wire (Bare Single or Tinned  Strand)
2.InsulationSR-PVC (Semi-Rigid Polyvinyl Chloride)  
2.Wrapping ShieldAnnealed Copper Wire (Bare Copper or Tinned Copper )
4.SheathPVC ( Polyvinyl  Chloride)  
5.Structure
    

Conductor

Insulation

Wrapping Shield

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

32

7 / 0.08TA

approx.0.24 mm

 0.51mm

0.18 mm

0.60 ± 0.10 mm

23 / 0.08

approx.0.76 mm

0.051mm

0.22mm

1.20 ± 0.10 mm

30

7 / 0.10TA

approx.0.30 mm

0.20 mm

0.70 ± 0.10 mm

22 / 0.10

approx.0.90 mm

0.051mm

0.225mm

1.40 ± 0.10 mm

28

7 / 0.13TA

approx.0.39 mm

0.205 mm

0.80 ± 0.10 mm

25 / 0.10

approx.1.00 mm

0.051mm

0.25mm

1.50 ± 0.10 mm

26

7 / 0.16TA

approx.0.48 mm

0.21 mm

0.90 ± 0.10 mm

28 / 0.10

approx.1.10 mm

0.051mm

0.275mm

1.65 ± 0.10 mm

24

7 / 0.20TA

approx.0.60 mm

0.20 mm

1.00 ± 0.10 mm

31 / 0.10

approx.1.20 mm

0.051mm

0.275mm

1.75 ± 0.10 mm

22

7 / 0.26TA

approx.0.78 mm

0.21 mm

1.20 ± 0.10 mm

36 / 0.10

approx.1.40 mm

0.051mm

0.275mm

1.95 ± 0.10 mm

20

42 / 0.13TA

approx.0.97 mm

0.39 mm

0.39 ± 0.10 mm

52 / 0.10

approx.1.95 mm

0.051mm

0.475mm

2.90 ± 0.10 mm

    NoteTATinned Copper ,  ABare  Copper

6.Characteristics

Items

Specification

Rating

UL80 30V

Dielectric Strength

AC 500V / min. (Between Conductor and Shield)

Spark Test AC 3000V / 0.15sec.

Insulation

Min.5MW - Km (20) at DC 500V

7.MarkingE54979 AWM  1533  80   VW – 1SC  AWG