UL  1533 / CSA  AWM  SR-PVC  Insulation Aluminum  Shield  Cable

   Figure
                 
1.ConductorAnnealed Copper Wire (Top-Tinned Strand or Tinned Single)
2.InsulationSR-PVC (Semi-Rigid Polyvinyl Chloride) 
3.Drain WireAnnealed Copper Wire (Top-Tinned Strand or Tinned Single)
4.ShieldAluminum-Mylar Tape (Thickness0.025mm )
5.SheathPVC ( Polyvinyl  Chloride)
6.Structure

Conductor

Insulation

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Al-Mylar
Tape

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

28

7 / 0.13ATC

approx.0.38mm

0.178 mm

0.26 mm

0.90 ± 0.10 mm

0.025 × 6 mm
longitudinal

7/0.13ATC
longitudinal

0.254mm

0.45mm

1.80 ± 0.10 mm
´2.20 ± 0.10 mm

26

1 / 0.41TA

approx.0.41 mm

0.178 mm

0.295 mm

1.00 ± 0.10 mm

0.025 × 6 mm
longitudinal

1/0.41ATC
longitudinal

0.254mm

0.47mm

1.95 ± 0.10 mm
´2.35 ± 0.10 mm

26

7 / 0.16ATC

approx.0.47 mm

0.178 mm

0.265 mm

1.00 ± 0.10 mm

0.025 × 6 mm
longitudinal

7/0.16ATC
longitudinal

0.254mm

0.44mm

1.95 ± 0.10 mm
´2.35 ± 0.10 mm

24

1 / 0.51TA

approx.0.51 mm

0.178 mm

0.295 mm

1.05 ± 0.10 mm

0.025 × 6 mm
longitudinal

1/0.51ATC
longitudinal

0.254mm

0.445mm

2.00 ± 0.10 mm
´2.50 ± 0.10 mm

24

7 / 0.20ATC

approx.0.58 mm

0.178 mm

0.26 mm

1.10 ± 0.10 mm

0.025 × 6 mm
longitudinal

7/0.20ATC
longitudinal

0.254mm

0.41mm

2.00 ± 0.10 mm
´2.50 ± 0.10 mm

    NoteTATinned Copper ,  ATCTop – Tinned  Strand

7.Characteristics

Items

Specification

Rating

UL80 ,  CSA80 30V

Dielectric Strength

AC 500V / min. 
(Between Conductor and Shield)

Spark Test AC 3000V / 0.15sec.

Insulation Resistance

Min.5MW - Km (20) at DC 500V

Mutual  Capacitance

Depends on Different Specifications (1KHz)

8.MarkingTATUNG  E54979 AWM  1533  80  VW – 1SC  AWG   TATUNG 
             
LL58500  CSA
AWM  I / II  A / B  80  30V  FT1