UL 1533 / CSA  AWM  SR-PVC  Shield Cable

   Figure
                 
1.ConductorAnnealed Copper Wire (Bare Single or Tinned  Strand)
2.InsulationSR-PVC(semi-Rigid Polyvinyl Chloride)  
3.Wrapping ShieldAnnealed Copper Wire (Bare Copper or Tinned Copper )
4.SheathPVC( Polyvinyl  Chloride)  
5.Structure

Conductor

Insulation

Wrapping  Shield

Sheath

AWG

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

30

7 / 0.10TA

approx.
0.30 mm

0.178mm

0.25 mm

0.80 ± 0.10 mm

25 / 0.10

1.00 mm

0.30mm

0.40mm

1.80 ± 0.10 mm

28

7 / 0.13TA

approx.
0.39 mm

0.255mm

0.90 ± 0.10 mm

28 / 0.10

1.10 mm

0.30mm

0.40mm

1.90 ± 0.10 mm

26

7 / 0.16TA

approx.
0.48 mm

0.245mm

0.97 ± 0.10 mm

31 / 0.10

1.17 mm

0.30mm

0.40mm

2.00 ± 0.10 mm

24

7 / 0.20TA

approx.
0.60 mm

0.25 mm

1.10 ± 0.10 mm

33 / 0.10

1.30 mm

0.30mm

0.40mm

2.10 ± 0.10 mm

22

7 / 0.26TA

approx.
0.78 mm

0.26 mm

1.30 ± 0.10 mm

39 / 0.10

1.50 mm

0.30mm

0.40mm

2.30 ± 0.10 mm

20

7 / 0.32TA

approx.
0.96 mm

0.27 mm

1.50 ± 0.10 mm

44 / 0.10

1.70 mm

0.30mm

0.40mm

2.50 ± 0.10 mm

6.Characteristics

Items

Specification

Rating

UL80  CSA80 300V

Dielectric Strength

AC 500V / min.
(Between Conductor and Shield)

Insulation Resistance

Min. 5MW - Km (20) at DC 500V

Flame Test

ULVW-1SC  CSAFT-1

Elongation of Insulation

Min.100

Tensile Strength of Insulation

Min.2.11Kg / mm2

Residual of Elongation after Aging

 Min. 70 of original (113℃,168H)

Residual of Tensile Strength after Aging

 Min. 70 of original (113℃,168H) 

7.MarkingE54979 AWM  1533  80  300V  VW – 1SC  AWG  TATUNG
              
LL58500  CSA  AWM  I / II  A / B  80  30V  FT1