UL  1365  Coaxial  Cable

   Figure
                 
1.ConductorAnnealed Copper Wire (Bare Single,Bare Strand or Tinned Strand) or
                
Copper-Plated Steel Wire.  
2.InsulationPE(Polyethylene)or XLPE (Cross-Linked Polyethylene)  
3.Braid ShieldAnnealed Copper Wire (Tinned Copper)
4.SheathPVC( Polyvinyl  Chloride)  
5.Structure

Conductor

CPE Insulation

Braid Shield

Sheath

AWG

Construction

Diameter

Min. Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

30

7 / 0.10A

approx.0.30 mm

0.508 mm

0.675 mm

1.65 ± 0.10 mm

16/5/0.10

approx.2.15mm

0.305mm

0.475mm

3.10 ± 0.20 mm

 

30

1 / 0.26ACP

approx.0.26 mm

0.695 mm

1.65 ± 0.10 mm

16/5/0.10

approx.2.15mm

0.305mm

0.475mm

3.10 ± 0.20 mm

 

28

1 / 0.32 ACP

approx.0.32 mm

0.84 mm

2.00 ± 0.10 mm

16/5/0.10

approx.2.50mm

0.305mm

0.75mm

4.00 ± 0.20 mm

 

28

1 / 0.32A

approx.0.32 mm

0.695 mm

2.00 ± 0.10 mm

16/5/0.10

approx.2.50mm

0.305mm

0.75mm

4.00 ± 0.20 mm

 

26

7 / 0.16A

approx.0.48 mm

0.685 mm

1.85 ± 0.10 mm

16/5/0.10

approx.2.35mm

0.305mm

0.575mm

3.50 ± 0.20 mm

 

24

7 / 0.20A

approx.0.60 mm

0.725 mm

2.05 ± 0.10 mm

16/5/0.10

approx.2.55mm

0.305mm

0.525mm

3.60 ± 0.20 mm

 

24

11 / 0.16TA

approx.0.61 mm

0.72 mm

2.05 ± 0.10 mm

16/5/0.10

approx.2.55mm

0.305mm

0.525mm

3.60 ± 0.20 mm

 

6.Characteristics

Items

Specification

Rating

UL60 300V

Dielectric Strength

AC 500V / min.(Between Conductor and Shield)

Spark Test AC 2000V / 0.15sec.

Insulation

Min.1000MW - Km (20) at DC 500V for PE

Min.50MW - Km (20) at DC 500V for FRPE

Flame Tesst

ULVW - 1

     NoteTATinned Copper ,  ABare Copper,  ACPCopper-Plated Steel
7.Marking   

Items

Specification

30

7/0.10(PE)

TATUNG  E54979 AWM  1365  60  VW-1  30AWG  75W  1.7C-2VS

30

7/0.10(FRPE)

TATUNG  E54979 AWM  1365  60  VW-1  30AWG

30

1/0.26ACP(PE)

TATUNG  E54979 AWM  1365  60  VW-1  30AWG  COPPER-CLAD  STEEL 75W  1.7C-2VCS

30

1/0.26ACP(FRPE)

TATUNG E54979 AWM  1365  60 VW-1  30AWG  COPPER-CLAD  STEEL

28

1/0.32 ACP(PE)

TATUNG  E54979 AWM  1365  60  VW-1  28AWG  COPPER-CLAD  STEEL 75W  2C-2VCS

28

1/0.32 (PE)

TATUNG  E54979 AWM  1365  60  VW-1  28AWG  75W  2C-2V

28

1/0.32 ACP(FRPE)

TATUNG E54979 AWM  1365  60