UL  1354  # 28 (ALB) Coaxial  Cable

   Figure
                 
1.ConductorAnnealed Copper Wire (Bare or Tinned Strand)
2.InsulationCPE ( Cellular Polyethylene)  
3.ShieldAluminum-Mylar Tape and Annealed Copper Wire (Tinned Copper )
4.SheathPVC  ( Polyvinyl  Chloride)  
5.Structure
 

Conductor

CPE Insulation

Braid Shield

Sheath

AWG

Construction

Diameter

Min. Thickness

Nominal
Thickness

Diameter

Construction

Diameter

Min.
Thickness

Nominal
Thickness

Diameter

28

7 / 0.13TA

approx.
0.41 mm

0.45 mm

0.53 mm

1.45 ± 0.10 mm

16/5/0.10

approx.
2.00 mm

0.36mm

0.55mm

3.10 ± 0.10 mm

6.Characteristics  

Items

Specification

Rating

UL80 30V

Dielectric Strength

AC 500V / min.
(Between Conductor and Shield)

Spark Test AC 2000V / 0.15sec.

Insulation Resistance

Min.1000MW - Km (20) at DC 500V


7.MarkingTATUNG  E54979 AWM  1354  80  28AWG