Extra High-Voltage Cross-Linked Polyethylene Insulated Power Cable (69kV~161 kV)

69KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables

It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A007.

161KV Grade Cross-Linked Polyethylene Insulated Polyvinyl Chloride Jacketed Cables

It is used at wiring for power distribution system. The cables shall comply with the standard of TPC A046.
Cross-Linked Polyethylene Insulated Power Cable (600V ~25kV)

600V~25KV Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Sheathed Cables

600V~25KV Cross-Linked Polyethylene Insulated and Polyvinyl Chloride Sheathed Cables. It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 2655.
Polyvinyl Chloride Insulated Power Cable

Polyvinyl chloride insulated wires

600V Polyvinyl chloride insulated wires (Code designation: IV). It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 679.

Polyvinyl Chloride Insulated and Sheathed Cables

It is used at wiring for power and equipment. The cables shall comply with the standard of CNS 3301.

Polyvinyl Chloride Insulated and Sheathed Control Cables

It is used at wiring for control circuit. The cables shall comply with the standard of CNS 4898.

Polyvinyl Chloride Insulated and Sheathed Control Cables with shields

It is used at wiring for control circuit. The cables shall comply with the standard of CNS 12726.
Ethylene Propylene Rubber Insulated Power Cable (600V~15kV)

600V~15kV EPRN Power Cable

It is used at wiring for power and equipment. It shall comply with the standards of ICEA.

2PNCT Power Cable

It shall comply with the standard of CNS 10741.

Hypalon Rubber Insulated Lead Wires

The Chlorosulfonated Polyethylene insulated lead wires (LHH) shall comply with the standard of CNS 5747.

Ethylene Propylene Rubber Insulated Lead Wires

The Ethylene Polyethylene insulated lead wires (LP) shall comply with the standard of CNS 5747.
Fire-Resistant & Heat-Resistant Wires & Cables

Fire-Resistant Power Cables

It is used at wiring for emergency power and fire-fighting equipment. The cables shall comply with the standard of CNS 11359.

Heat-Resistant Power Cable

It is used at wiring for control circuit of fire-fighting equipment. The control cables shall comply with the standard of CNS 11175.

Mica layer, Cross-Linked Polyethylene Insulated, Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables

It is used at wiring for emergency power and fire-fighting equipment. The cables shall comply with the standard of CNS 11359 .

600V Heat-Resistance Polyvinyl chloride insulated wires

It is used at fixed wiring for building and equipment. The wires shall comply with the standard of CNS 8379.
Low Smoke Halogen Free Wires & Cables

Cross-Linked Polyethylene Insulated and Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power and Control Cables

It is used at wiring for power and control circuit of distribution system. The control cables shall comply with the standard of IEC 60502.

Cross-Linked Polyethylene Insulated, steel wires armor and Low-Smoke and Halogen-Free (LSHF) Compound Jacketed Power Cables

It is used at wiring for power distribution system. The power cables shall comply with the standard of IEC 60502.
Bus Duct System

H-P Bus Duct System

The "bus-duct" system is one for effective and efficient supply of electricity borne of valuable resources.

T2-HP Fire Resistance Bus Duct System

The "bus-duct" system is one for effective and efficient supply of electricity borne of valuable resources. The standards applied to the 600V bus duct shall be CNS 14286, IEC 439-2, JIS C 8364,NEMA BU1.